Design and Experiment of Elastic Force Detection and Disassembly Integration Equipment for Elastic Ring of Dust Filter Bag
To address issues such as the high labor intensity of manual evaluation and disassembly of the elastic rings used in dust filter bags, we designed elastic force detection and disassembly integration equipment for an elastic ring of the dust filter bag. First, we tested the elasticity and deformation of the elastic rings under radial pressure in a constrained state. We then proposed the working principle of the equipment for elasticity testing and ring disassembly. Subsequently, we conducted structural design, prototype fabrication, assembly, and debugging. Utilizing the equipment developed in this study, we performed experiments to investigate the factors affecting both the elasticity testing of the elastic rings and the disassembly process. The results indicated that the main cylinder’s push depth, push position, and push force of the disassembly cylinder, set at 90 mm, b, and 80 N, respectively, successfully enabled the disassembly of the dust filter bag’s elastic rings.
Elastic Ring
除尘滤袋是袋式除尘器的核心部件,是由纺织而成的滤布或非纺织而成的毡制成。如
刘冬基于塑性铰坍塌模型分析了径向荷载与位移的理论表达式,对压头形状、尺寸及加载方式等因素对圆管截面塑性变形规律及吸能特性的影响进行了试验
国内外学者关于圆环承受径向压力的研究主要从试验与数值分析两方面开展,取得了较多的研究结果,但是对除尘滤袋弹性圆环约束状态下受径向压力及变形的研究报道不多。本文拟先开展除尘滤袋弹性圆环约束状态下受径向压力及变形试验,设计一种滤袋弹性圆环压力检测与弹性圆环拆卸装置,再开展该装置的运行参数优化试验。
滤袋弹性圆环弹检测原理如
滤袋弹性圆环拆卸工作原理如
采用YG026H型多功能电子织物强力机检测花板圆孔约束状态下滤袋弹性圆环弹力。取直径为125 mm、145 mm、155 mm的碳钢和不锈钢两种成品滤袋弹性圆环各五个,测试花板圆孔约束状态下滤袋弹性圆环弹力。
由
滤袋弹性圆环压力检测与弹性圆环拆卸装置是一种集成了滤袋弹性圆环压力检测和圆环拆卸功能的自动化装置,由弹性圆环弹力检测机构、由弹性圆环拆卸机构、拆卸气缸平面导轨机构、花板夹紧机构、电控系统、气动系统以及机架平台等部分组成。
如
如
如
传感器受到滤袋弹性圆环向下作用时,弹性测点就会出现微小变形,附着在弹性测点上的弹性应变片也会出现微小变形,影响到电桥的电阻值,从而形成压差信号,经A/D转换电路将滤波后的电压信号转换成可利用的数字信号。
本文采用纳威克(NVK) KA2高精度称重传感器,该传感器工作稳定、精度较高的单点式压力传感器,灵敏度为2.0 ± 0.2% m V/V,量程为0~60 KG,能够满足于大多数工作场合。
设计完成的滤袋弹性圆环弹力检测与弹性圆环拆卸装置总体结构如
在进行滤袋弹性圆环拆卸与压力检测装置性能测试之前,对滤袋弹性圆环压力检测机构电阻应变片式传感器进行标定,得到相应电压值所对应的弹性圆环压力大小。在标定试验中,将花板夹紧机构和弹性圆环压力检测机构顶板做整体标定,标定结果如
得到滤袋弹性圆环压力检测机构的输出电压(y)与负载(x)的关系曲线,用MATLAB对试验数据进行拟合,函数关系为y = 0.016x – 0.5646,R2为0.988。
选取材料为60钢的滤袋弹性圆环为试件,采用滤袋弹性圆环压力检测装置做压力检测试验。制备直径为220 mm,宽度为30 mm,厚度为0.5 mm的滤袋弹性圆环。用数据采集卡和显示仪表记录滤袋弹性圆环弹力–位移值,结果如
弹性圆环径向压缩量L/mm |
数据采集卡测试值N |
仪表显示值N |
偏差/% |
10 |
154.66 |
156.32 |
1.07 |
20 |
77.23 |
78.47 |
1.61 |
30 |
62.31 |
64.57 |
3.63 |
40 |
55.12 |
56.33 |
2.20 |
50 |
50.88 |
52.68 |
3.54 |
60 |
49.64 |
50.24 |
1.21 |
70 |
48.45 |
49.86 |
2.91 |
80 |
48.18 |
49.52 |
2.78 |
使用滤袋表条压力检测装置测得的滤袋表条压力最大偏差百分比为3.63%,最小偏差百分比为1.07%,平均偏差百分比为2.37%。说明滤袋弹性圆环弹力检测装置有较高的准确性,满足工程应用要求。
试验因素 |
|||||
序号 |
主气缸推压深度x1/(mm) |
拆卸气缸推压位置x2 |
拆卸气缸推力x3/(N) |
拆卸气缸速度x4/(mm/s) |
初始距离x5/(mm) |
1 |
30 |
a |
20 |
50 |
10 |
2 |
60 |
b |
40 |
100 |
30 |
3 |
90 |
c |
60 |
150 |
50 |
4 |
120 |
80 |
200 |
70 |
|
5 |
150 |
100 |
250 |
90 |
拆卸气缸推压位置为b、拆卸气缸推力为60 N、拆卸气缸速度为150 mm/s、拆卸气缸和滤袋弹性圆环之间的初始距离为50 mm时,主气缸推压深度对可拆卸指数的方差分析F的统计量为3.565,显著性水平为0.023,说明主气缸推压深度对拆卸效果有影响;主气缸推压深度在90 mm时,拆卸效果最佳。
主气缸推压深度为90 mm、拆卸气缸推力为60 N、拆卸气缸速度为150 mm/s、拆卸气缸和滤袋弹性圆环之间的初始距离为50 mm时,拆卸气缸推压位置对可拆卸指数方差分析F的统计量为15.043,显著性水平约为0,拆卸气缸推压位置对拆卸效果有影响。当拆卸气缸推压位置在a时,拆卸效果最差;拆卸气缸推压位置在b时,拆卸效果最佳。
主气缸推压深度为90 mm、拆卸气缸推压位置为b、拆卸气缸速度为150 mm/s、拆卸气缸和滤袋弹性圆环之间的初始距离为50 mm时,拆卸气缸推力对可拆卸指数的方差分析F的统计量为214.212,显著性水平约为0,拆卸气缸推力对拆卸效果有影响。拆卸气缸推力为80N时拆卸效果最佳。
卸气缸速度和初始距离对可拆卸指数的方差分析结果,F的统计量分别为0.312和1.694,显著性水平分别为0.869和0.168。说明这两个因素对拆卸效果影响不显著。
1) 开展了除尘滤袋弹性圆环约束状态下受径向压力及变形试验,滤袋弹性圆环约束状态下径向弹力最大值约为200 N,产生最大径向弹力时的径向压缩量为20 mm。
2) 设计了一种滤袋弹性圆环压力检测与弹性圆环拆卸一体化装置,对组成该装置的弹性圆环压力检测机构、弹性圆环拆卸机构、拆卸气缸平面导轨机构、花板夹紧机构进行了结构设计,并设计了电控系统、气动系统等。
3) 确定了对滤袋弹性圆环拆卸机构的影响因素,开展了滤袋弹性圆环拆卸试验,结果表明:主气缸推压深度、拆卸气缸推压位置、拆卸气缸推力对拆卸效果有显著影响,其值分别为90 mm、b、80 N时拆卸效果最佳;拆卸气缸推头速度、拆卸气缸和滤袋弹性圆环之间的初始距离对拆卸效果没有显著影响。
辽宁省教育厅高校基本科研项目(202210148037)。2023年大学生创新创业训练计划立项项目(202310148005)。
*通讯作者。